CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
CANopen Product Guide 2008
home

ifm electronic

www.ifm-electronic.com

NMT
NMT slave
Error control
Node guarding,
Life guarding,
Heartbeat producer,
Heartbeat consumer
Boot-up
Yes
Node ID
Hardware switch,
Software switch,
Proprietary
No. of PDO
RPDOs
4
TPDOs
4
PDO modes
Event-triggered,
Triggered by event-timer,
Synchronous (cyclic)
PDO linking
Yes
PDO mapping
Variable
No. of SDO
Server
1
Client
No
Emergency message
Emergency producer
Sync
No
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
Self-starting device,
Program download
Supported application layer
CiA 301 V 4.0.2
Supported frameworks
None
Supported profiles
CiA 401: CANopen device profile for generic I/O modules
Certified
No

Address

ifm electronic gmbh
Teichstr. 4
DE-45127 Essen

Phone: +49-201-24220
Fax: +49-201-2422200
Email: info@ifm-electronic.com
URL: www.ifm-electronic.com/

Technical contact

Service Center ifm electronic gmbh

Phone: +49-1803-436463
Fax: +49-1802-436329
Email: info@ifm-electronic.com

Sales contact

Service Center ifm electronic gmbh

Phone: +49-1803-436463
Fax: +49-1802-436329
Email: info@ifm-electronic.com

Austria

ifm electronic gmbh

Phone: +43-1-6174500
Fax: +43-1-617450010
Email: info.at@ifm-electronic.com

Finland

ifm electronic oy

Phone: +358-75-3295000
Fax: +358-75-3295010
Email: info.fi@ifm-electronic.com

France

ifm electronic s.a.

Phone: +33-1-48106000
Fax: +33-1-48106011
Email: info.fr@ifm-electronic.com

Italy

ifm electronic s.a.

Phone: +39-039-6899982
Fax: + 39-039-6899995
Email: info.it@ifm-electronic.com

North America and Mexico

ifm efector, inc.

Phone: +1-800-4418246
Fax: +1-800-3290436
Email: info@ifmefector.com

Spain

ifm electronic s.a.

Phone: +34-93-4793080
Fax: +34-93-4793086
Email: info.es@ifm-electronic.com

Sweden

ifm electronic ab

Phone: +46-325-661500
Fax: +46-325-661590
Email: info.se@ifm-electronic.com

United Kingdom

ifm electronic ltd.

Phone: +44-208-2130000
Fax: +44-208-2130001
Email: enquiry_gb@electronic.com

R360 CabinetModule (truck, off-highway, railway)

Availability
In stock

Large mobile machines often have cabins for the operators. There are many signals in the area around the driver's workplace, e. g. from switches, joysticks or signal lamps. In order to connect these signals to the process control at a low cost, the signals are collected in a central module, preprocessed and transmitted to the controller via CANopen.

The decentralised CAN module CR2016 provides the opportunity to use the inputs and outputs precisely in those positions in the cabin or in the operating panel where they are required. Thus wiring complexity is considerably reduced. Due to the parameter setting of the input and output functions, the module can be flexibly adapted to the corresponding application. The flat design is ideal for integration in dashboards, operating panels and control panels. The compact plastic housing provides all the necessary connections for the 16 inputs and 16 outputs and the communication. The connectors for mobile use can be locked and are reverse-polarity protected. The status LEDs for the inputs and outputs as well as the LEDs for power / communication and error are located behind a transparent service lid. Using the coding switches which are also located there, the node number and the baud rate can be directly set.

The module provides high flexibility due to the configuration of the inputs and outputs. There is a choice of analog and digital inputs. The function of the analog inputs can be set as current input 0 mA to 20 mA or as voltage input 0 V to 10 V and as ratiometric voltage input 0 V to 32 V. As regards the ratiometric input, the analog value is read without additional reference voltage, only by internally reading back the supply voltage. A fluctuation of the supply voltage has no influence on the measured value. The short-circuit and overload-protected outputs can be used as digital and PWM outputs. All input / output functions are configured from the user program via the object directory. Setting of the bit-rate and the node number is done via CANopen commands or via the integrated coding switches.

R360 CabinetModule, CR2016

  • Mechanical resistance to extreme shock
  • Supply voltage 10 VDC to 32 VDC
  • Load-dump resistance
  • CAN interfaces with CANopen protocol for communication (CiA 401 V2.1, CiA 301 V4.02)
  • Four analog inputs, can also be configured as:
    • Analog input, voltage
    • Analog input, current
    • Digital input
  • Four digital inputs
  • Four digital inputs, can also be configured as:
    • Inputs for negativ signals
  • Four digital inputs, can also be configured as:
    • Frequency inputs
  • Four digital outputs (2 A), can also be configured as:
    • PWM output
  • Twelve digital outputs
  • CE, e1 type approval, approval for railway applications (EN 50155)