NMT
NMT slave
Error control
Heartbeat producer
Boot-up
Yes
Node ID
Software switch,
Proprietary
No. of PDO
RPDOs
1
TPDOs
1
PDO modes
Triggered by event-timer
PDO linking
Yes
PDO mapping
Static
No. of SDO
Server
1
Client
None
Emergency message
Emergency producer
Sync
No
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
None
Supported application layer
CiA 301 V 4.0.2,
CiA 301 V 4.1
Supported frameworks
None
Supported profiles
CiA 401: CANopen device profile for generic I/O modules
Certified
No

Headquarters

TK Engineering Oy
Wolffintie 36 F2 / III
FI-65200 Vaasa

Phone: +358-6-3576300
Fax: +358-6-3576320
Email: info@tke.fi
URL: www.tke.fi

DIN-A CANopen valve driver interface

Availability
In stock

CANopen DIN-A valve driver is a new approach to integrate existing hydraulic valves with CANopen-network. This unit gives a very cost efficient CANopen interface individually for each coil. Thanks to its design it can be mounted to most valves on the market.

Operational modes

The CANopen DIN-A valve has got three different operational modes:

  • On-off
  • Positive direction open-loop PWM
  • Negative direction open-loop PWM

Current monitoring is active in all operating modes.

CANopen interface

The physical CAN interface in the DIN-A valve driver is according to ISO 11898-2 high-speed CAN physical layer. Cost-optimized CANopen interface is according to the following standards:

  • CiA 301 version 4.1.1
  • CiA 303-1 version 1.4
  • CiA 401 version 2.1.9

Connectors

CANopen DIN-A valve has got Bosch Compact type dual connector for power supply and CAN. Valve coil connector is 2-pole DIN 43650-A/ISO 4400.

Some features of DIN-A valve driver

  • Power from the CAN network
  • Compact dimensions 35 mm × 50 mm × 75 mm
  • Meets CiA 301, CiA 303-1 and CiA 401
  • RPDO timeout monitoring
  • Automatic output shutdown on RPDO timeout
  • Automatic thermal shutdown of the output

Features of CANopen DIN-A valve driver

  • RPDO timeout monitoring with automatic shutdown on error
  • Continuous coil current monitoring in all operating modes
  • Continuous temperature monitoring
  • Supply voltage 7 VDC to 36 VDC
  • ±4 kV contact discharge and ±8 kV HMB air discharge for power supply and CAN
  • Supply Current max. 175 mA typ. 75 mA
  • Output current max. 2 000 mA
  • Operating temperature −VDC40 °C to +85 °C
  • Environmental protection IP65+
  • CAN bit-rate 125 kbit/s, 250 kbit/s, 500 kbit/s, 800 kbit/s, 1 Mbit/s
  • CAN voltage tolerance up to ±36 VDC
  • Dimensions (W × H × L) 35 mm × 50 mm × 75 mm