CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
CANopen Product Guide 2008
home

Deutschmann Automation

www.deutschmann.de

NMT
NMT slave
Error control
Node guarding
Boot-up
Yes
Node ID
Hardware switch
No. of PDO
RPDOs
1
TPDOs
1
PDO modes
Event-triggered, Synchronous (acyclic)
PDO linking
No
PDO mapping
Static
No. of SDO
Server
1
Client
1
Emergency message
No
Sync
No
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
None
Supported application layer
CiA 301 V 3.0
Supported frameworks
None
Supported profiles
None
Certified
No

Headquarters

Deutschmann Automation
P.O. 1108
DE-65516 Bad Camberg

Phone: +49-6434-94330
Fax: +49-6434-943340
Email: info@deutschmann.de
URL: www.deutschmann.de

All worldwide agents are listed on our website

Unigate CANopen-Profibus DP gateway

Availability
In stock

Communication can be split into seven layers, layer 1 to layer 7, in accordance with the ISO/OSI reference model.

The Deutschmann Automation gateways convert layers 1 and 2 of the corresponding bus systems. Layers 3 to 6 are blank, and layer 7 is converted in accordance with the configured mapping.

The gateway can be configured through the software Wingate® that is also supplied.

This gateway module from the Unigate range of Deutschmann Automation allows a coupling between ProfibusDP and CANopen.

Here the gateway on the CANopen side acts as a standard-compliant master and on the ProfibusDP side as a standard-compliant slave so that the problems that appear again and again (to couple the CANopen device to a Siemens PLC with ProfibusDP) are solved.

Like all Unigate modules this gateway is also developed for the practical industrial use. It has 9 LEDs available that allow the user an easy diagnosis.

Like the complete Unigate family, the gateway can be configured via the Windows software "Wingate®" that is available free of charge.