ESD Electronic System Design

www.esd-electronics.com

NMT
NMT slave, NMT master
Error control
Heartbeat producer, Heartbeat consumer
Boot-up
Yes
Node ID
Software switch
No. of PDO
RPDOs
128
TPDOs
128
PDO modes
Event-triggered, Triggered by event-timer, Remotely-requested, Synchronous (cyclic), Synchronous (acyclic)
PDO linking
No
PDO mapping
Static
No. of SDO
Server
1
Client
No
Emergency message
Emergency producer, Emergency consumer
Sync
Yes
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
None
Supported application layer
CiA 301 V 3.0, CiA 301 V 4.0.2
Supported frameworks
None
Supported profiles
None
Certified
No

Headquarters

ESD Electronic System Design
Vahrenwalder Str. 207
DE-30165 Hannover

Phone: +49-511-372980
Fax: +49-511-3729868
Email: info@esd-electronics.com
URL: www.esd-electronics.com

Sales contact

Gino Raffa

Phone: +49-511-372980
Fax: +49-511-3729868
Email: gino.raffa@esd-electronics.com

Technical contact

Harm-Peter Krause

Phone: +49-511-372980
Fax: +49-511-3729868
Email: harm-peter.krause@esd-electronics.com

Japan

Yoshiki Yamada

Email: jp-sales@esd-electronics.com

USA/Canada

ESD Electronics
Michelle Dzialo
525 Bernardston Road, Suite 1
US-01301 Greenfield, MA

Phone: +1-800-732-8006
Fax: +1-800-732-8093
Email: michelle.dzialo@esd-electronics.com

Please ask for your local representative outside these countries!

CANopen-DP gateway

Availability
In stock
  • Fast and reliable linking Profibus-DP and CANopen networks with data buffering
  • CAN-PLC link, e.g. to Siemens S7-300 or S7-400
  • 244 bytes input and 244 bytes output Profibus data

Linking Profibus-DP and CANopen

The module CANopen-DP can link any Profibus-DP master to a CANopen network. The gateway operates as a Profibus-DP slave-I/O component with a total of maximum 244 bytes input and 244 bytes output data. It supports cyclic (DP-V0) as well as acyclic (DP-V1) Profibus data transfers.

On CANopen it operates as a CANopen manager supporting CANopen master, NMT master and configuration functions. PDO and SDO (with SDO timeout and MPDO transmission) data transfers are supported.
Start frame, Sync and Heartbeat are controlled by the module.

Applications

With the CANopen-DP gateway you can couple CANopen modules to e.g. a Simatic-S7. The number of CANopen devices is not limited by the module.

Physical interfaces

The ISO 11898-compatible CAN interface allows a maximum bit-rate of 1 Mbit/s. The Profibus-DP-Slave interface automatically recognizes all usual bit-rates up to 12 Mbit/s. The Profibus-DP as well as the CAN interface are electrically isolated.

Configuration and CAN protocols

The module can be configured via Profibus configuration tool, e.g. the PLC Simatic manager. CANopen is supported as CAN-layer-7 protocol on the CAN layer. Additionally CAN-layer-2 functions are available.

Coming soon:
CANopen-PN: Profinet-IO CANopen gateway
CANopen-EtherCAT: EtherCAT CANopen gateway