www.tke.fi

NMT
NMT slave
Error control
Heartbeat producer
Boot-up
Yes
Node ID
Software switch,
LSS-services,
Proprietary
No. of PDO
RPDOs
3
TPDOs
6
PDO modes
Event-triggered,
Triggered by event-timer
PDO linking
No
PDO mapping
Variable
No. of SDO
Server
1
Client
None
Emergency message
Emergency producer
Sync
No
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
LSS slave
Supported application layer
CiA 301 V 4.0.2
Supported frameworks
CiA 305
Supported profiles
CiA 401: CANopen device profile for generic I/O modules,
CiA 413: CANopen device profiles for truck gateways
Certified
No

Headquarters

TK Engineering Oy
Wolffintie 36 F2 / III
FI-65200 Vaasa

Phone: +358-6-3576300
Fax: +358-6-3576320
Email: info@tke.fi
URL: www.tke.fi

PE552 I/O module and J1939 gateway

Availability
In stock

The PE552 is the compact and robust 16-bit microcontroller I/O module with CANopen functionality. Additionally this device provides CANopen gateway to J1939 engine/network.

Technical details

  • Operating voltage 7 VDC to 30 VDC
  • Separate power supply pins for the microcontroller and outputs
  • Microcontroller's power consumption max. 2,5 Watt, typically 60 mA @ 24 V
  • Protected against overvoltage and faulty voltage polarity
    The reverse polarity protection does only work, when the supply voltage for outputs is fused (~16 A) and a short circuit is switched off after 50 to 250 ms.
  • Note!
    A power supply with a current control/limit or a wrong fuse results the destruction of the module in the case of reversed polarity.
  • 8 × digital outputs
    • Output type 24 V p-switching, max continuous current 2,5 A/output
    • Configurable to ON/OFF outputs or to PWM outputs with selectable frequency
    • Max output current on 7/8, power supply connector 13 A
  • 8 × digital inputs
    • Input type 24 V p-switching
    • 2 × inputs for frequency and PWM measuring
    • 2 × inputs for a quadrature encoder
  • 4 × analog inputs
    • 0 mA to 20 mA measuring range
    • 60 W serial resistance and 237 W shunt resistance to GND
    • Overvoltage protected
  • CAN bus interfaces (ISO11898)
    • CAN1:
      • CANopen protocol - CiA 301 V4.02
      • CANopen device profile for generic I/O modules - CiA 401 V2.0
      • Supports LSS - Layer Setting Services - CiA 305 V2.0
      • CANopen device profile for truck gateways - CiA 413 V1.02
      • (J1939 Gateway) bit-rate up to 1 Mbit/s
    • CAN2:
      • Connection to J1939 engine
      • Bit-rate 250 kbit/s
      • Internal 120 W bus termination
  • Operating temperature range −40 °C to 70 °C
  • Storage temperature range −50 °C to 85 °C
  • Stainless steel housing, PUR casting in bottom side
  • Protection class IP67
  • Weight ∼720 g