CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
CANopen Product Guide 2008
home

Port

www.port.de

Headquarters

Port GmbH
Regensburger Str. 7b
DE-06132 Halle/Saale

Phone: +49-345-777550
Fax: +49-345-7775520
Email: service@port.de
URL: www.port.de

Sales contact

Hartmut Tietz

Phone: +49-345-7775510
Email: ti@port.de

Technical contact

Heinz-Jürgen Oertel

Phone: +49-345-7775522
Email: oe@port.de

Benelux

SI-Kwadraat B.V.

Phone: +31-40-2846656
Fax: +31-40-2838092
Email: info@si-kwadraat.nl
URL: www.si-kwadraat.nl

France

NeoMore

Phone: +33-1-30641581
Fax: +33-1-30640883
Email: sales@neomore.com
URL: www.neomore.com

Italy

ECS Srl

Phone: +39-0437-33101
Fax: +39-0437-359631
Email: service.canopen@ecsproject.com
URL: www.ecsproject.com

Spain

Sistemas Embebidos S.A.

Phone: +34-941-270060
Fax: +34-941-237770
Email: pperez@embebidos.com
URL: www.embebidos.com

United Kingdom

Warwick Control Technologies Ltd.

Phone: +44-1676-536010
Fax: +44-1676-536219
Email: sales@warwickcontrol.com
URL: www.warwickcontrol.com

USA

Pyramid Solutions, Inc.

Phone: +1-248-5491200
Fax: +1-248-5491400
Email: gbeal@pyramid-solutions.com
URL: www.pyramid-solutions.com


Embedded Solutions

Phone: +1-888-5469741
Fax: +1-888-5469741
Email: info@es-usa.com
URL: www.es-usa.com


Please see our homepage for further distributors:
http://www.port.de/engl/company/company.html

CAN-REport analyzer tool

Availability
In stock

CAN-REport

Overview

The CAN-Analyzer  CAN-REport of port is an efficient and versatile tool for analysis and commissioning of CAN-based networks like CANopen, DeviceNet and J1939. The built-in scripting capability allows to use it universally for development and test of CAN devices besides the normal possibilities of displaying the received CAN messages. It is especially useful in the field of industrial CAN networking.

Application

In the standard equipment the CAN-REport already has a lot of efficient basic functions like on-line observation of the bus traffic, transmission of unique or cyclic CAN messages, trigger inclusive pre- and post-trigger logging and whole message sequences as well as the recording of CAN messages and the storage to log files belong to this purpose. Log files can be loaded again and interpreted with activated extensions.

Among other things the on-line observation of the bus traffic, the transmitting of unique or cyclic CAN messages and whole message sequences as well as the recording of CAN messages and the storage to log files belong to this purpose.

The analyzer CAN-REport consists of the CAN hardware interface and the visualization software.  Both are connected as server and client by a standard TCP/IP network connection. This separation allows to use the CAN interface as a remote interface, i.e. both parts can be located on different computer systems.  Remote monitoring of CAN networks is possible without additional or modified software over LAN, dial or Internet connections.

CAN interfaces are currently available for USB, ISA, PCI, parallel port, serial port and PC-104 or an Ethernet interface  like the stand-alone CAN-Server port-EtherCAN or IGW/900.

CANopen/DeviceNet/J1939 Extension

Supplementary software modules provide extended functionality like service and protocol dependent interpretation of CAN messages. For the higher layer protocols CANopen, DeviceNet and J1939 a service dependent protocol interpretation is available.

The CANopen extension displays CAN messages of the services

  • SDO
  • PDO
  • NMT
  • EMCY
  • Flying Manager
  • LSS

in separate windows.

Extension for redundant CAN networks

Redundant CAN networks are in use in  medical equipments or in maritime  CANopen applications.

In different cases it is necessary to observe both CAN networks in a temporal cohesion at the fault diagnosis and when commissioning the network and network devices.

CAN-REport supports with this extension module the parallel representation of two networks.

Programmability

For the interpretation of company internal protocols an extension can be developed and loaded into CAN-REport. Such an extension is realized with the built-in scripting language Tcl/Tk and is simplified by provided functions.

With the scripting language also elements of the graphical interface can be extended to match individual needs. It is possible to use provided or own graphical objects to create test and control applications. With the help of the multifaceted possibilities for displaying and reporting data, test sequences can be carried out automatically even from a remote working place.

The user and protocol specific configurations and extensions of the CAN-REport can be done in the menu "Configure". Furthermore these special settings can be saved for additional tests at a later time.

Trigger

CAN-REport provides the trigger functionality to wait for specific CAN messages and continue logging after the specific CAN message was received. The trigger dialog consists of the three parts "Trigger Event", "Action at trigger event" and "Logfile options". Up to three different  CAN messages can be specified as trigger.

Interactivity

With the help of the integrated console convenient commands for accessing the CAN network interactively are available. These commands can be used in test scripts.

The commands can be combined into sequences or procedures. All semantics of modern high level languages are available.

Particularly for commissioning and error analysis a precise time resolution of the received CAN messages at the network is necessary. The time represented by CAN-REport is influenced only by the used hardware. Time resolution up to 1 µs can be achieved by using CAN interface boards under the Linux operating system.

port can perform special adoptions to the GUI or behavior to meet special customer requirements for service or assembly testing.

Buy the products or download free demo versions at: