CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
CANopen Product Guide 2008
home

Beckhoff Automation

www.beckhoff.com

NMT
NMT slave,
NMT master
Error control
Node guarding,
Heartbeat producer,
Heartbeat consumer
Boot-up
Yes
Node ID
Hardware switch,
Proprietary
No. of PDO
RPDOs
32
TPDOs
32
PDO modes
Event-triggered,
Triggered by event-timer,
Remotely-requested,
Synchronous (cyclic),
Synchronous (acyclic)
PDO linking
Yes
PDO mapping
Variable
No. of SDO
Server
1
Client
8
Emergency message
Emergency producer,
Emergency consumer
Sync
No
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
None
Supported application layer
CiA 301 V 4.1
Supported frameworks
CiA 302: CANopen additional application layer functions
Supported profiles
CiA 401: CANopen device profile for generic I/O modules,
CiA 402: CANopen device profile for drives and motion control,
CiA 404: CANopen device profile measuring devices and closed-loop controllers,
CiA 405: CANopen interface and device profile for IEC 61131-3 programmable devices,
CiA 406: CANopen device profile for encoder
Certified
No

Headquarters

Beckhoff Automation GmbH
Eiserstr. 5
DE-33415 Verl

Phone: +49-5246-9630
Fax: +49-5246-963198
Email: info@beckhoff.com
URL: www.beckhoff.com

Technical contact

Beckhoff Automation GmbH
Office Nuremberg
Martin Rostan
Ostendstr. 196
DE-90482 Nuremberg

Phone: +49-911-5405611
Fax: +49-911-5405629
Email: nuernberg@beckhoff.com

Austria

Beckhoff Automation GmbH
Hauptstr. 4
AT-6706 Bürs

Phone: +43-5552-688130
Fax: +43-5552-6881318
Email: info@beckhoff.at
URL: www.beckhoff.at

China

Beckhoff Automation GmbH
Room 1608, Tower B
Investment Plaza
Financial Street 27
CN-100032 Beijing, Xicheng District

Phone: +86-10-66210991
Fax: +86-10-66210992
Email: info@beckhoff.com.cn
URL: www.beckhoff.com.cn

Finland, Estonia

Beckhoff Automation Oy
P.O. Box 23
Kankurinkatu 4-6
FI-05801 Hyvinkää

Phone: +358-20-7423800
Fax: +358-20-7423801
Email: info@beckhoff.fi
URL: www.beckhoff.fi

Italy

Beckhoff Automation S.r.l.
Via E. Majorana, 1
IT-20054 Nova Milanese, MI

Phone: +39-03-62-365164
Fax: +39-03-62-40990
Email: info@beckhoff.it
URL: www.beckhoff.it

Poland

Beckhoff Automation SP.z.o.o.
Stara Iwiczna, ul. Sloneczna 116A
PL-05500 Piaseczno

Phone: +48-22-7572610
Fax: +48-22-7572607
Email: info@beckhoff.pl
URL: www.beckhoff.pl

Russia

Representation of Beckhoff Automation GmbH
Naberezhnaya Akademika
Tupolewa 15 kor.2
RU-107005 Moscow

Phone: +7-495-9808015
Fax: +7-495-980-8016
Email: russia@beckhoff.com
URL: www.beckhoff.ru

Sweden, Norway

Beckhoff Automation AB
Stenådersgatan 2B
SE-21376 Malmö

Phone: +46-40-6808164
Fax: +46-40-6808161
Email: info@beckhoff.se
URL: www.beckhoff.se

Switzerland

Beckhoff Automation AG
Rheinweg 9
CH-8200 Schaffhausen

Phone: +41-52-6334040
Fax: +41-52-6334055
Email: schaffhausen@beckhoff.ch
URL: www.beckhoff.ch

USA, Canada, Mexico

Beckhoff Automation LLC
12204 Nicollet Avenue South
US-55337 Burnsville, MN

Phone: +1-952-8900000
Fax: +1-952-8902888
Email: beckhoff.usa@beckhoff.com
URL: www.beckhoffautomation.com

BX5100 bus terminal controller

Availability
In stock

The BX5100 bus terminal controller offers a high degree of flexibility. The controller is a slave device towards a higher-level CANopen network and acts as CANopen master on the underlying CANopen system (Smart System Bus SSB). Thus the BX5100 is the ideal device for modular systems with distributed control architecture.

Besides the two CANopen interfaces, the IEC 61131-3 controller provides a K-bus interface for the connection of the Beckhoff Bus Terminals. Additionally, the BX devices are equipped with two serial interfaces: one for programming, the other for free utilisation. Furthermore, the BX features an illuminated LCD display with two lines of 16 characters each, a joystick switch and a real-time clock.

The CANopen interfaces support all CANopen PDO transmission types. The local PLC communicates data via network variables mapped in PDOs. The CANopen master interface on the BX5100 is intended for up to eight devices with four PDOs each.

The controller is programmed with TwinCAT in all five IEC 61131-3 languages. Programming and online debugging can be done via CANopen or serial interface.