CANopen LioN-Link system I/O modules
In stock
The LioN-Link system consists of bus coupler modules which provide the connection between the entire fieldbus system and the fieldbus independent I/O modules. Based on a BusHead, the I/O module is distributed decentrally to the field via two lines. A total of 15 devices per branch can be connected to the system for a total extension of 100 m per branch.
The wiring of the LioN Link modules uses simple standard wiring components such as actuator/sensor cord sets, single or double ended, for the I/OÕs and for the power supply or CAN/DeviceNet thin cables for the link connection. This means that no manufacturer-specific wiring components are required. Because of that, the system offers a cost optimized and cost transparent wiring solution which is installed in the plug-and-play procedure and put into operation. No terminator is necessary for the connection of the last LioN Link module in a line.
| Degree of protection | IP 67 |
| Operating temperature | −10 °C to +60 °C |
| Node ID | 1 to 99 dec |
| Default Address | 63 dec |
You will find all technical information at our Website in detail.
Following types are available:
BusHead
- 0940 CSL 601 BusHead CANopen
LioN-Link module universal I/O digital
- 0942 UEM 600: 8 in/out universal 4 × M12
- 0942 UEM 650: 8 in/out universal 8 × M8
- 0942 UEM 700: 16 in/out universal 8 × M12
- 0942 UEM 780: 16 In/out universal multipole cable interface
LioN-Link module output digital
- 0942 UEM 780: 16 out multipole cable interface
LioN-Link module input digital
- 0942 UEM 601: 8 in 4 × M12
- 0942 UEM 651: 8 in 8 × M8
- 0942 UEM 701: 16 In 8 × M12