CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
CANopen Product Guide 2008
home

Sensor-Technik Wiedemann

www.sensor-technik.de

NMT
NMT slave
Error control
Heartbeat producer,
Heartbeat consumer
Boot-up
Yes
Node ID
Hardware switch,
Software switch
No. of PDO
RPDOs
2
TPDOs
10
PDO modes
Event-triggered,
Synchronous (cyclic),
Synchronous (acyclic)
PDO linking
Yes
PDO mapping
Dynamic
No. of SDO
Server
1
Client
No
Emergency message
Emergency producer
Sync
No
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
Network variables
Supported application layer
CiA 301 V 4.0.2
Supported frameworks
None
Supported profiles
CiA 401: CANopen device profile for generic I/O modules
Certified
No

Headquarters

Sensor-Technik Wiedemann GmbH
Steuer- und Regelelektronik
Am Bärenwald 6
DE-87600 Kaufbeuren

Phone: +49-8341-95050
Fax: +49-8341-950555
Email: info@sensor-technik.de
URL: www.sensor-technik.de

Sales contact

Klaus Gnahm (Electronic Controller Systems)

Phone: +49-8341-95050
Fax: +49-8341-950555
Email: Email: sales@sensor-technik.de

Great Britain

Sensor-Technik UK Ltd.
Unit 10, The Granary
Mill Road, Sharnbrook
GB-MK44 1NN  Bedfordshire

Phone: +44-1234-782049
Fax: +44-1234-782056
Email: sales@sensor-technik.co.uk
URL: www.sensor-technik.co.uk

USA

STW-Technic, LP
Mobile controllers and measurement technologies
3000 Northwoods Pkwy. Suite 206
US-30071 Norcross, GA

Phone: +1-770-2421002
Fax: +1-770-2421006
Email: sales@stw-technic.com
URL: www.stw-technic.com

ESX-IOX I/O module

Availability
In stock

The ESX-IOX is a low cost I/O module for mobile applications, which provides a lot of I/O for less money. The total current output is 10 A.

The following I/O is possible with ESX-IOX:

  • Up to 28 digital inputs
  • Up to two RPM inputs
  • Up to six voltage inputs (0 V to 10 V)
  • Up to twelve voltage inputs (0 V to 40 V)
  • Up to four PWM outputs
  • Up to eight digital outputs
  • Up to four digital outputs low active
  • Up to one 10 V output for the supply of sensors

It extends the I/O capability of a master controller using CAN (CANopen protocol or layer 2 communications).

The module is mounted in a plastic housing (approx. 136 mm × 117 mm × 36 mm).

Depending on your specific needs, it can be ordered in different options.

Connection is provided by a single 42-pin-connector from Tyco.