CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
CANopen Product Guide 2008
home

Sensor-Technik Wiedemann

www.sensor-technik.de

NMT
NMT slave
Error control
Node guarding,
Life guarding
Boot-up
No
Node ID
Hardware switch,
Software switch
No. of PDO
RPDOs
2
TPDOs
2
PDO modes
Event-triggered,
Remotely-requested,
Synchronous (cyclic),
Synchronous (acyclic)
PDO linking
Yes
PDO mapping
Static
No. of SDO
Server
1
Client
No
Emergency message
Emergency producer
Sync
No
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
Network variables
Supported application layer
CiA 301 V 3.0
Supported frameworks
None
Supported profiles
CiA 401: CANopen device profile for generic I/O modules
Certified
No

Headquarters

Sensor-Technik Wiedemann GmbH
Steuer- und Regelelektronik
Am Bärenwald 6
DE-87600 Kaufbeuren

Phone: +49-8341-95050
Fax: +49-8341-950555
Email: info@sensor-technik.de
URL: www.sensor-technik.de

Sales contact

Klaus Gnahm (Electronic Controller Systems)

Phone: +49-8341-95050
Fax: +49-8341-950555
Email: Email: sales@sensor-technik.de

Great Britain

Sensor-Technik UK Ltd.
Unit 10, The Granary
Mill Road, Sharnbrook
GB-MK44 1NN  Bedfordshire

Phone: +44-1234-782049
Fax: +44-1234-782056
Email: sales@sensor-technik.co.uk
URL: www.sensor-technik.co.uk

USA

STW-Technic, LP
Mobile controllers and measurement technologies
3000 Northwoods Pkwy. Suite 206
US-30071 Norcross, GA

Phone: +1-770-2421002
Fax: +1-770-2421006
Email: sales@stw-technic.com
URL: www.stw-technic.com

ESX-DIOS/DIOM of I/O modules family

Availability
In stock
  • I/O modules for mobile applications extends the I/O capability of a master controller using the CAN network (CANopen protocol or layer 2 communication)
  • ESX-DIOS: I/O module with max. eight outputs and two inputs or max. ten inputs
  • ESX-DIOM: I/O module with max. 24 outputs and two inputs or max. 26 inputs
  • Customer specific default settings for bit-rate and module basis address, software configurable
  • Automatic detection of nine different slot positions (module coding) using two tristate pins All outputs are diagnosable
  • All inputs and outputs are protected against over voltage and against short circuit to ground / supply voltage
  • Safety-relay as switch-off alternative
  • Direct driving of proportional valves saves additional driver and / or controller boards
data table