CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
CANopen Product Guide 2008
home

Eckelmann

www.eckelmann.de

NMT
NMT master
Error control
Node guarding
Boot-up
No
Node ID
No
No. of PDO
RPDOs
127
TPDOs
127
PDO modes
Event-triggered,
Remotely-requested,
Synchronous (cyclic)
PDO linking
No
PDO mapping
Variable
No. of SDO
Server
1
Client
127
Emergency message
Emergency consumer
Sync
Yes
Sync producer:
No
Sync counter:
Time stamp
No
Additional functions
None
Supported application layer
CiA 301 V 4.0.2
Supported frameworks
None
Supported profiles
CiA 401: CANopen device profile for generic I/O modules,
CiA 402: CANopen device profile for drives and motion control,
CiA 406: CANopen device profile for encoder
Certified
No

Headquarters

Eckelmann
Berliner Str. 161
DE-65205 Wiesbaden

Phone: +49-611-71030
Fax: +49-611-7103133
Email: info@eckelmann.de
URL: www.eckelmann.de

Embedded controller ExC66

Availability
In stock

The universal ExC66 hardware platform, whose communications options ensure usability in the future. Apart from the particularly powerful PowerPC processor MPC5200, the technical highlights of the ExC66 include the possibility of convenient and cheap memory extension by means of an SD card. The new controller provides more fieldbus interfaces (4x CAN, 1x real-time Ethernet), further communication paths (USB, RS-232C). Its openness to international standards such as Devicenet, Powerlink, Ethernet IP etc. makes it a flexible central unit for universal use. The new local bus modules E•LBM (digital and analog I/Os and axis interface) which are especially designed for the EXC66 have unique design features for time-critical applications.

The ExC66 is also comfortable combinable with the own intelligent CAN fieldbus modules in the series ECKELMANN E•FBM.

Programmable as:

  • PLC: with programming tool CoDeSys according to IEC 61131-3.
  • Motion control: with additional motion library (up to 64 axes).
  • CNC: with NC operating system, standard HMI for PC and DIN programming (up to 12 axes).

Following local bus modules are available:

  • Axis interface module LBM-ARI01
  • Terminal module LBM-CON16
  • Digital input module LBM-DIM16
  • Digital output module LBM-DOM16
  • Power supply module LBM-PWR04
  • Analog input/output module LBM-AIO22