CAN in Automation (CiA)
headquarters@can.cia.org
www.can-cia.org
Switch to the CAN products section CAN and J1939 Product Guide 2011 J1939 product section CAN and J1939 Product Guide 2011
home

Peak-System Technik

www.peak-system.com

Headquarters

Peak-System Technik GmbH
Otto-Roehm-Str. 69
DE-64293 Darmstadt

Phone: +49-6151-817320
Fax: +49-6151-817329
Email: info@peak-system.com
URL: www.peak-system.com

Sales contact

Michael Maidhof

Phone: +49-6151-817322
Fax: +49-6151-817329
Email: sales@peak-system.com

France

Peak-System SARL France
23, Boulevard de l'Europe
FR-54500 Vandoeuvre-lés-Nancy

Phone: +33-38354-1520
Fax: +33-38354-1521
Email: france@peak-system.com
URL: www.peak-system.com

Great Britain

Computer Solutions Ltd.
1a New Haw Road
GB-KT15 2BZ Addlestone, SRY

Phone: +44-1932-829460
Fax: +44-1932-84003
Email: sales@computer-solutions.co.uk
URL: www.computer-solutions.co.uk

USA

Grid Connect Inc.
1841 Centre Point Circle, Suite 143
US-60563 Naperville, IL

Phone: +1-630-245-1445
Fax: +1-630-245-1717
Email: sales@gridconnect.com
URL: www.gridconnect.com

Phytec America LLC
203 Parfitt Way SW, Suite G100
US-98110 Bainbridge Island, WA

Phone: +1-206-780-9047
Fax: +1-206-780-9135
Email: info@phytec.com
URL: www.phytec.com

For further distributers worldwide, please refer to www.peak-system.com > contact > distributors

PCAN-Explorer 5 analyzer and diagnostic tool

Availability
In stock

Comprehensive CAN monitor for Windows 7/Vista/XP (32/64-bit)

PCAN-Explorer is a universal tool for monitoring data traffic on a CAN network. For easy and clear allocation of the individual messages, these can be identified as so-called symbols. The integrated VB-Script support allows the creation of macros to automate complex tasks. The integrated data logger means that the data traffic of a bus can be recorded, analyzed, and stored. PCAN-Explorer is designed as automation server and can therefore be remote controlled through scripts.

Features

  • All files and elements can be managed and saved in projects
  • Project components such as CAN connections, symbol files and macros are clearly displayed and laid out in the project browser
  • The new start page allows fast access to the most recently opened projects or files
  • Simultaneous connections with up to 16 networks/CAN interfaces of the same hardware type
  • Connection window with an overview of all connections, complete with status, error counters, bus load, etc.
  • All parameters of all elements in the user interface can be examined using a property window and edited if necessary
  • Multiple flexible filters can be configured and, for example, assigned to the transmit/receive window or the various different tracers
  • Tabs to switch between the different windows
  • Flexible arrangement of the user interface using the dockable windows
  • User-defined column display and arrangement in transmit/receive window
  • J1939-support with the relevant add-in
  • Display of received messages showing the ID, length, data bytes, number of messages received and receiving interval
  • Simultaneous hexadecimal and symbolic representation of the details
  • Display of remote frames, status reports of the CAN controller and, as option, CAN network error frames also
  • Logging of time-outs
  • Sending of messages at fixed intervals of time, manually or as reply to remote frames
  • Messages can be created as send lists, stored and loaded as desired, in order to e.g., emulate CAN nodes
  • Periodical sending with up to 1 ms precision
  • Easy creation of symbol files and macros using the integrated text editor with syntax highlighting
  • User-friendly real-time monitoring of several signals via the watch window
  • Extensive improvements to user guidance and interface compared to PCAN-Explorer version 4
  • User interface language can be switched (German/English)
  • Simple integration of external tools
  • Integration of add-ins to upgrade functionality

Properties of the integrated, configurable PCAN-Explorer data logger

  • Operation of multiple tracers at the same time
  • Variable buffer size
  • Optional linear buffer or circular buffer
  • Representation of the logged messages with time stamp, type, ID, length and data bytes
  • Logging of errors that have occurred is possible
  • Flexible storage possibility for the logged data in text form for importing into Excel or similar
  • Filtering of the messages for logging through symbol definitions
  • Subsequent examination of the logged data in the buffer via different symbol files

Function upgrade of the PCAN-Explorer with the integrated VB-Script language

  • Creation of macros in VB-Script with the integrated text editor
  • Access with macros and scripts to almost all program elements via the PCAN-Explorer object model
  • Ideal for creating test tools to implement or develop CAN systems
    • Examples
    • Sending of e-mails when a temperature is exceeded
    • Starting of a test tool when a particular message is received
    • Opening of an Excel sheet when an event occurs and saving of data in the individual cells
  • Assignment of function keys with individual send messages or macros
  • VBS scripts run in the background even without the PCAN-Explorer interface

Properties of the independent PCAN symbol editor

  • Symbolic representation of CAN messages through the assigning of alphanumeric names
  • Bit-exact division of the data into variables for assigning name, data type, list of values, scaling, offset etc.
  • Supports data processing in accordance with IEEE 754 as well as in the Intel and Motorola format
  • Set up user-defined outputs using lists of values (Enums)
  • Use of multiplexers for outputting CAN data of a single CAN-ID with different symbol definitions
  • The graphic representation of symbols and the automatic error detection allow easy creation of symbol files
  • The item navigator and the search function allow targeted access to all elements of the symbol files
  • Creation of virtual variables for CAN-independent inputs and outputs and macro calculations (in conjunction with PCAN-Explorer only)
  • Importing of CANdb files into the symbol data format and vice versa (requires the PCAN-Explorer add-in CANdb Import)
  • Supports symbols for J1939 message formats (requires the PCAN-Explorer add-in J1939)

The J1939 add-in for PCAN-Explorer 5

The J1939 add-in for PCAN-Explorer 5 supports all definitions established by the standard's parameter groups and provides a simple means of accessing the parameters. A complete database of all the definitions and the parameters contained is also supplied.

Features

  • Support of all functions of the SAE J1939 network protocol
  • CAN messages can be sent in broadcast form or targeted to individual control units (ECUs)
  • Addressing of up to 254 ECUs
  • Supports multi-packet messages

Scope of supply

  • PCAN-Explorer installation CD including PCAN-Explorer line writer add-in
  • PCAN Symbol Editor for Windows 7/Vista/XP (32/64-bit)
  • Documentation in HTML help format

Optional

  • J1939 add-in
  • Plotter add-in
  • CANdb import add-in
  • Instruments panel add-in