Basic-Terminal human machine interface
In stock
Basic-Terminal complies with the Isobus-Standard ISO 11783. As a universal terminal it is manufacturer-independent and can be used with all machines that comply with the Isobus-Standard. Baisc-Terminal provides all basic functions needed to to operate Isobus machines.
Connections
Basic-Terminal has three connectors signed as A, B and C.
+Vin and -Vin serve the voltage supply. The signals marked with *) correspond to CiA 303-1 allocation.
The signals CAN_L and CAN_H are connected internally and are for looping through the CAN network. When TBC_PWR_in is put on the voltage (= +Vin), the terminal can be switched on. When switched on, the terminal delivers the distribution voltage (minus 1,2 V) with maximum 140 mA on TBC_PWR_out for the supply of the terminator networks.
Pin Signal
1 CAN_L
6 -Vin *)
2 CAN_L *)
7 CAN_H *)
3 TBC_GND *)
8 TBC_PWR_out
4 CAN_H
9 +Vin
5 TBC_PWR_in
The connector B is the second CAN interface which can be used e.g. as a J1939 interface. The connector C is an RS-232 interface with 12-V power supply on pin 4 for a GPS receiver and +5 V on pin 9 for Bluetooth.
Technical data
Operating voltage: 10 V to 24 V
Operating temperature: -10 °C to +70 °C
Storage temperature: -20 °C to +70 °C
Weight: 1,3 kg
Measurements (L x W x H): 220 mm x 210 mm x 95 mm
Protection class IP64 according to DIN 40050/15
EMC according to ISO 14982 / PREN 55025 / Level 4
ESD protection according to ISO 10605 Level 3
Current consumption max. 0,5 A (< 5 W)
Display VGA (320 pixel × 240 pixel) monochrome



Müller-Elektronik