SIG04 Measuring devices
Scope
Enhancement and maintenance of the profile for measuring devices and closed-loop controllers including pressure, force, and temperature sensors: CiA 404 - Measuring devices and closed-loop controllers.
Chairperson
Uwe Koppe, MicroControl
Minutes
Title | Date | Status | Size | Published | Action |
---|---|---|---|---|---|
SIG measuring devices | 2016-05-09 | Minutes | 111 KiB | 2017-07-18 | Login |
Workshop: Measuring devices and closed-loop controls | 2023-02-07 | Minutes | 14.9 MiB | 2023-04-25 | Login |
IG03 SIG04 Measuring devices | 2023-05-25 | Minutes | 226 KiB | 2023-07-17 | Login |
IG03 SIG04 Measuring devices | 2023-08-07 | Minutes | 124 KiB | 2023-08-24 | Login |
IG03 SIG04 Measuring devices | 2023-10-12 | Minutes | 124 KiB | 2023-11-15 | Login |
Specification
Title | Details | Status Size |
Published Action |
---|---|---|---|
CiA 404-2 version 2.0.0CANopen profile for measuring devices and closed-loop controllers - Part 2: EUROMAP implementation | DescriptionThis specification represents the device profile for measuring devices and for universal controller devices for measuring or controlling physical quantities like temperature or pressure. These devices use communication techniques which are conform to those described in /CiA301/.
The CANopen device profile for measuring devices and closed-loop controllers consists of several parts:
• Part 1 defines the generic objects and the generic PDO mapping
• Part 2 defines the EUROMAP specific parameters
This part specifies the additional objects needed for EUROMAP 75 measuring amplifiers
parameters and EUROMAP 66 heating/cooling device parameters.
Keywordsn/a | DSP441 KiB | 2013-08-01Login |
CiA 404-1 version 2.1.0CANopen device profile for measuring devices and closed-loop controllers – Part 1: Generic objects and generic PDO mapping | DescriptionThis document specifies the device profile for measuring devices and for universal controller devices for measuring or controlling of physical quantities such as temperature or pressure. The CANopen device profile for measuring devices and closed-loop controllers consists of two parts: Part 1 defines the generic objects and the generic PDO mapping. Part 2 defines the EUROMAP specific parameters. This part specifies the parameter for the digital input and output blocks resp. the analog input and output blocks. Additionally, it specifies the alarm and control as well as the device function block. Keywordsn/a | DSP3.1 MiB | 2016-07-19Login |
CiA 404-B version 0.0.1Profile for measuring devices and closed-loop controllers Part B: Functional behaviour and application parameters | Descriptionn/a Keywordsn/a | WDP2.5 MiB | 2023-09-19Login |
CiA 404-C version 0.0.1Profile for measuring devices and closed-loop controllers Part C: CANopen mapping | Descriptionn/a Keywordsn/a | WDP312 KiB | 2023-09-19Login |
CiA 404-F version 0.0.1Profile for measuring devices and closed-loop controllers Part F: CANopen FD mapping | Descriptionn/a Keywordsn/a | WDP305 KiB | 2023-09-19Login |
IG profiles groups
Name | Description |
---|---|
SIG01 Generic I/O devices | ScopeEnhancement and maintenance of the profile for generic I/O modules and special-purpose I/O devices such as joysticks and foot-pedals: CiA 401 - Modular I/O devices; CiA 852 - Recommended practice for CiA 401-based operator environment sub-systems. ChairmanChristian Keydel, Embedded Systems Academy |
SIG02 Drives and motion control | ScopeEnhancement and maintenance of the profiles for electrical drives including frequency inverters, servo controllers, and stepper motors: CiA 402 (IEC 61800-7-201/301) - Drives and motion controllers; CiA 452 - PLCopen Motion devices. Chairmanvacant |
SIG03 Encoder and inclinometer | ScopeEnhancement and maintenance of profiles for inclinometer as well as for linear and rotary encoders: CiA 406 - Encoder; CiA 410 - Inclinometer. ChairmanKlaus Matzker, Fraba |
SIG04 Measuring devices | ScopeEnhancement and maintenance of the profile for measuring devices and closed-loop controllers including pressure, force, and temperature sensors: CiA 404 - Measuring devices and closed-loop controllers. ChairmanUwe Koppe, MicroControl |
SIG05 Fluid power | ScopeEnhancement and maintenance of the profile for fluid power technology proportional valves and hydrostatic transmissions such as hydraulic proportional valves, pumps, and drives: CiA 408 - Fluid-power devices. ChairmanMartin Schindelin, Moog |
SIG06 Lift control | ScopeEnhancement and maintenance of the profile for lift (elevator) control systems comprising call, car drive, and door controllers as well as panel, door, car drive, and other units: CiA 417 - Lift control systems. Chairmanvacant |
SIG08 Contrast media injector | ScopeEnhancement and maintenance of profiles for medical add-on devices such as contrast media injector: CiA 425 - Contrast-media injector; CiA 312-4 - CiA 425 conformance test plan. ChairmanRon Kong, Bayer Healthcare |
SIG10 Fire-fighting | ScopeDeveloping and maintaining embedded body application profiles for fire-fighting subsystems (e.g. aerial working platforms, container units, stabilizer units, DIN 14700 systems, etc.) and the mapping to Classic CANopen. Additionally, the SIG develops and maintains DIN 4630 interfaces for fire-fighting subsystems. ChairmanDagmar Schymonski-Dederichs, ifm ecomatic |
SIG11 Municipal vehicles | ScopeEnhancement and maintenance of the profile for refuse collecting vehicles and profiles for other municipal equipment such as weeper and winter service vehicles: CiA 422 (EN 16815) - Refuse-collecting vehicle devices. ChairmanThomas Kemner, C-Trace |
SIG14 Special-car add-on devices | ScopeEnhancement and maintenance of profiles for special-purpose car add-on devices such as roof bar, digital radio, taximeter, equipment for disabled people, and in-vehicle gateway: CiA 447 - Special-purpose car add-on devices; CiA 412-5 - CiA 447 conformance test plan. ChairmanOlaf Pfeiffer, Embedded Systems Academy |
SIG15 Subsea | ScopeEnhancement and maintenance of profile sub-sea instruments such as sensors and meters as well as valves: CiA 443 (ISO 13628-6) - SIIS level-2 devices. ChairmanHarald Schuhmacher, OneSubsea |
SIG16 Energy management systems | ScopeEnhancement and maintenance of profiles for energy management systems that may operate in mobile applications (e.g. light-electric vehicles) as well as non-mobile applications (e.g. isolated farms): CiA 454 (IEC TS 61851-3-4/5/6/7) - Energy management system; CiA 312-7 - CiA 454 conformance test plan.
ChairmanSteffen Rose, emotas |
SIG18 IO-Link | ScopeEnhancement and maintenance of the profile for IO-Link gateways: CiA 463 - IO-Link gateway. ChairmanJoachim Uffelmann, ifm ecomatic |
SIG19 Welding and cutting | ScopeThe SIG develops and maintains an application profile for advanced manual arc welding and plasma cutting systems; connections to robots and overarching systems are out of scope.
The profile provides plug-and-play functionality for basic setups, including physical layer requirements such as compatible cables and connectors. The resulting system provides contradiction-free data to the Asset Administration Shell (AAS) and facilitates regulatory compliance and protecting the worker’s health.
ChairmanDr. Andreas Matz, Abicor Binzel |