SIG16 Energy management systems

Scope

Enhancement and maintenance of profiles for energy management systems that may operate in mobile applications (e.g. light-electric vehicles) as well as non-mobile applications (e.g. isolated farms): CiA 454 (IEC TS 61851-3-4/5/6/7) - Energy management system; CiA 312-7 - CiA 454 conformance test plan.

Chairperson

Steffen Rose, emotas

Meetings

Date Time* Group Location
2024-06-04 10:00 - 12:00 IG03 SIG16 Energy management systems e-meeting

* Local time at CiA office, Nuremberg, Germany.

Minutes

Title Date Status Size Published Action
JTF CiA/EnergyBus: EMS2017-02-14Minutes2.0 MiB2017-07-17Login
JTF CiA/EnergyBus: EMS2017-06-09Minutes1.9 MiB2017-07-17Login
JTF CiA/EnergyBus: EMS2017-06-23Minutes1.7 MiB2017-07-17Login
JTF CiA/EnergyBus: EMS2016-12-21Minutes2.3 MiB2017-07-18Login
JTF CiA/EnergyBus: EMS2016-12-14Minutes2.9 MiB2017-07-18Login
JTF CiA/EnergyBus: EMS2016-06-29Minutes120 KiB2017-07-18Login
JTF CiA/EnergyBus: EMS2017-07-20Minutes132 KiB2017-08-01Login
JTF CiA/EnergyBus: EMS2018-05-22Minutes345 KiB2018-05-23Login
JTF CiA/EnergyBus: EMS2018-06-29Minutes135 KiB2018-07-03Login
JTF CiA/EnergyBus: EMS2018-09-06Minutes2.5 MiB2018-09-11Login
JTF CiA/EnergyBus: EMS2018-12-06Minutes3.4 MiB2019-01-22Login
JTF CiA/EnergyBus: EMS2019-04-03Minutes395 KiB2019-04-09Login
IG profiles JSIG CiA/EnergyBus: EMS2019-09-11Minutes1.5 MiB2019-09-23Login
IG profiles JSIG CiA/EnergyBus: EMS2019-10-14Minutes2.7 MiB2019-10-18Login
IG profiles JSIG CiA/EnergyBus: EMS2019-11-13Minutes1.8 MiB2019-12-17Login
IG profiles JSIG CiA/EnergyBus: EMS2019-12-19Minutes114 KiB2019-12-20Login
IG profiles JSIG CiA/EnergyBus: EMS2020-03-26Minutes125 KiB2020-04-22Login
IG profiles JSIG CiA/EnergyBus: EMS2020-04-30Minutes621 KiB2020-05-05Login
IG profiles: SIG EMS2020-06-04Minutes115 KiB2020-06-25Login

Specifications

Title Details
Status
Size
Published
Action
CiA 454-14 version 1.0.0CANopen application profile for energy management systems - Part 14: Load unit
DescriptionThe CANopen application profile for EMSs specifies the communication interface for all virtual devices that may take part in energy management control application. Such energy management control applications may be implemented in e.g. light electric vehicles, robots, offshore parks, isolated farms, etc. The CANopen application profile for EMSs consists of the following parts: Part 1: General definitions, Part 2: Pre-defined communication parameters and general application objects, Part 3: Pre-defined PDO communication, Part 4: EMS controller, Part 5: Voltage converter unit, Part 6: Battery pack, Part 7: Motor control unit (under development), Part 8: Load monitoring unit (under development), Part 9: HMI unit (under development), Part 10: Security unit (under development), Part 11: Sensor unit (under development), Part 12: Gateway unit (under development), Part 13: Generator unit, Part 14: Load unit. This document represents the part 14 of the CANopen application profile for EMSs. Part 14 of the document specifies load units such as lighting, electrical motor, radio, refrigerator, washing machine, etc. Loads shall be divided into three classes: controllable loads, influenceable loads and non-controllable loads.
Keywordsn/a
DSP453 KiB2014-06-17Login
CiA 454-7 version 1.0.0CANopen application profile for energy management systems - Part 7: Drive control unit
DescriptionThis document specifies application objects provided by the drive control unit, as typically utilized in light electric vehicles.
Keywordsn/a
DSP665 KiB2021-04-06Login
CiA 454-2 version 2.0.0CANopen application profile for energy management systems - Part 2: Pre-defined communication parameters and general application objects
DescriptionThe CANopen application profile for EMSs specifies the communication interface for all virtual devices that may take part in energy management control application. Such energy management control applications may be implemented in e.g. light electric vehicles, robots, offshore parks, isolated farms, etc. The CANopen application profile for EMSs consists of the following parts: Part 1: General definitions, Part 2: Pre-defined communication parameters and general application objects, Part 3: Pre-defined PDO communication, Part 4: EMS controller, Part 5: Voltage converter unit, Part 6: Battery pack, Part 7: Motor control unit (under development), Part 8: Load monitoring unit (under development), Part 9: HMI unit (under development), Part 10: Security unit (under development), Part 11: Sensor unit (under development), Part 12: Gateway unit (under development), Part 13: Generator unit, Part 14: Load unit. This document represents the part 2 of the CANopen application profile for EMSs. Part 2 provides additional specifications with regard to the pre-defined communication objects as well as the general communication objects.
Keywordsn/a
DSP2.0 MiB2014-06-17Login
CiA 454-1 version 2.0.0CANopen application profile for energy management systems - Part 1: General definitions
DescriptionThe CANopen application profile for EMSs specifies the communication interface for all virtual devices that may take part in energy management control application. Such energy management control applications may be implemented in e.g. light electric vehicles, robots, offshore parks, isolated farms, etc. The CANopen application profile for EMSs consists of the following parts: Part 1: General definitions, Part 2: Pre-defined communication parameters and general application objects, Part 3: Pre-defined PDO communication, Part 4: EMS controller, Part 5: Voltage converter unit, Part 6: Battery pack, Part 7: Motor control unit (under development), Part 8: Load monitoring unit (under development), Part 9: HMI unit (under development), Part 10: Security unit (under development), Part 11: Sensor unit (under development), Part 12: Gateway unit (under development), Part 13: Generator unit, Part 14: Load unit. This document represents the part 1 of the CANopen application profile for EMSs. Part 1 provides the general concept of the EMS.
Keywordsn/a
DSP1.5 MiB2014-06-17Login
CiA 454-13 version 1.0.0CANopen application profile for energy management systems - Part 13: Generator unit
DescriptionThe CANopen application profile for EMSs specifies the communication interface for all virtual devices that may take part in energy management control application. Such energy management control applications may be implemented in e.g. light electric vehicles, robots, offshore parks, isolated farms, etc. The CANopen application profile for EMSs consists of the following parts: Part 1: General definitions, Part 2: Pre-defined communication parameters and general application objects, Part 3: Pre-defined PDO communication, Part 4: EMS controller, Part 5: Voltage converter unit, Part 6: Battery pack, Part 7: Motor control unit (under development), Part 8: Load monitoring unit (under development), Part 9: HMI unit (under development), Part 10: Security unit (under development), Part 11: Sensor unit (under development), Part 12: Gateway unit (under development), Part 13: Generator unit, Part 14: Load unit. This document represents the part 13 of the CANopen application profile for EMSs. Part 13 of the document specifies generator units such as a diesel engine, photovoltaic generator, winds turbine, etc. Generators shall be divided into two classes: Controllable and stochastic generator.
Keywordsn/a
DSP533 KiB2014-06-17Login
CiA 454-5 version 2.0.0CANopen application profile for energy management systems - Part 5: Voltage converter
DescriptionThe CANopen application profile for EMSs specifies the communication interface for all virtual devices that may take part in energy management control application. Such energy management control applications may be implemented in e.g. light electric vehicles, robots, offshore parks, isolated farms, etc. The CANopen application profile for EMSs consists of the following parts: Part 1: General definitions, Part 2: Pre-defined communication parameters and general application objects, Part 3: Pre-defined PDO communication, Part 4: EMS controller, Part 5: Voltage converter unit, Part 6: Battery pack, Part 7: Motor control unit (under development), Part 8: Load monitoring unit (under development), Part 9: HMI unit (under development), Part 10: Security unit (under development), Part 11: Sensor unit (under development), Part 12: Gateway unit (under development), Part 13: Generator unit, Part 14: Load unit. This document represents the part 5 of the CANopen application profile for EMSs. Part 5 provides application objects provided by the AC-DC converter. The AC-DC converter may be implemented to realize a battery charger or a charger station.
Keywordsn/a
DSP2.0 MiB2014-06-17Login
CiA 454-9 version 1.0.0CANopen application profile for energy management systems - Part 9: HMI unit
DescriptionThis document specifies application objects provided or indicated by human machine interface units, as typically utilized in light electric vehicles. This comprises human machine interface units, managing data for signalling, travelling, battery systems, inputs for energy management user condition and state, motion and diagnostics.
Keywordsn/a
DSP283 KiB2021-04-06Login
CiA 454-6 version 2.0.0CANopen application profile for energy management systems - Part 6: Battery pack
DescriptionThe CANopen application profile for EMSs specifies the communication interface for all virtual devices that may take part in energy management control application. Such energy management control applications may be implemented in e.g. light electric vehicles, robots, offshore parks, isolated farms, etc. The CANopen application profile for EMSs consists of the following parts: Part 1: General definitions, Part 2: Pre-defined communication parameters and general application objects, Part 3: Pre-defined PDO communication, Part 4: EMS controller, Part 5: Voltage converter unit, Part 6: Battery pack, Part 7: Motor control unit (under development), Part 8: Load monitoring unit (under development), Part 9: HMI unit (under development), Part 10: Security unit (under development), Part 11: Sensor unit (under development), Part 12: Gateway unit (under development), Part 13: Generator unit, Part 14: Load unit. This document represents the part 6 of the CANopen application profile for EMSs. Part 6 of the document specifies application objects provided by the battery pack.
Keywordsn/a
DSP1.3 MiB2014-06-17Login
CiA 454-3 version 3.0.0CANopen application profile for energy management systems - Part 3: PDO communication
DescriptionThis document specifies the PDO communication and mapping parameters.
Keywordsn/a
DSP1.0 MiB2021-04-06Login
CiA 454-4 version 2.0.0CANopen application profile for energy management systems - Part 4: EnergyBus controller
DescriptionThe CANopen application profile for EMSs specifies the communication interface for all virtual devices that may take part in energy management control application. Such energy management control applications may be implemented in e.g. light electric vehicles, robots, offshore parks, isolated farms, etc. The CANopen application profile for EMSs consists of the following parts: Part 1: General definitions, Part 2: Pre-defined communication parameters and general application objects, Part 3: Pre-defined PDO communication, Part 4: EMS controller, Part 5: Voltage converter unit, Part 6: Battery pack, Part 7: Motor control unit (under development), Part 8: Load monitoring unit (under development), Part 9: HMI unit (under development), Part 10: Security unit (under development), Part 11: Sensor unit (under development), Part 12: Gateway unit (under development), Part 13: Generator unit, Part 14: Load unit. This document represents the part 3 of the CANopen application profile for EMSs. Part 3 specifies the application objects provided by the virtual device Energy management system controller (EBC).
Keywordsn/a
DSP337 KiB2014-06-17Login
CiA 312-7 version 1.0.0CANopen profile conformance test plans - Part 7: Pedelec Profile 1
DescriptionThis document provides the conformance test specification for devices implemented according to CiA 454, Part 1, 2, 3, 4, 5, and 6 version 2.0.
Keywordsn/a
DSP568 KiB2020-03-03Login
CiA 854 version 0.0.1CANopen recommended practice
Descriptionn/a
Keywordsn/a
WD1.8 MiB2020-04-21Login