CANopen JTF CiA/EnergyBus: Energy management systems (EMS)

Scope

Enhancement and maintenance of CANopen profiles for energy management systems that may operate in mobile applications (e.g. light electric vehicles) as well as non-mobile applications (e.g. isolated farms).

Chairmen

Steffen Rose, emtas

Group meetings

No events found.

Minutes

Title Date Status Size Published Action
JTF CiA/EnergyBus: EMS2017-02-14Minutes2.0 MiB2017-07-17Login
JTF CiA/EnergyBus: EMS2017-06-09Minutes1.9 MiB2017-07-17Login
JTF CiA/EnergyBus: EMS2017-06-23Minutes1.7 MiB2017-07-17Login
JTF CiA/EnergyBus: EMS2016-12-21Minutes2.3 MiB2017-07-18Login
JTF CiA/EnergyBus: EMS2016-12-14Minutes2.9 MiB2017-07-18Login
JTF CiA/EnergyBus: EMS2016-06-29Minutes120 KiB2017-07-18Login
JTF CiA/EnergyBus: EMS2017-07-20Minutes132 KiB2017-08-01Login
JTF CiA/EnergyBus: EMS2018-05-22Minutes345 KiB2018-05-23Login
JTF CiA/EnergyBus: EMS2018-06-29Minutes135 KiB2018-07-03Login
JTF CiA/EnergyBus: EMS2018-09-06Minutes2.5 MiB2018-09-11Login

Specifications

Title Details
Status
Size
Published
Action
CiA 454-1 version 2.0.0CANopen application profile for energy management systems – Part 1: General definitions
DescriptionThe CANopen application profile for EMSs specifies the communication interface for all virtual devices that may take part in energy management control application. Such energy management control applications may be implemented in e.g. light electric vehicles, robots, offshore parks, isolated farms, etc. The CANopen application profile for EMSs consists of the following parts: Part 1: General definitions, Part 2: Pre-defined communication parameters and general application objects, Part 3: Pre-defined PDO communication, Part 4: EMS controller, Part 5: Voltage converter unit, Part 6: Battery pack, Part 7: Motor control unit (under development), Part 8: Load monitoring unit (under development), Part 9: HMI unit (under development), Part 10: Security unit (under development), Part 11: Sensor unit (under development), Part 12: Gateway unit (under development), Part 13: Generator unit, Part 14: Load unit. This document represents the part 1 of the CANopen application profile for EMSs. Part 1 provides the general concept of the EMS.
Keywordsn/a
DSP1.2 MiB2014-06-17Login
CiA 454-2 version 2.0.0CANopen application profile for energy management systems – Part 2: Pre-defined communication parameters and general application objects
DescriptionThis document represents the part 2 of the CANopen application profile for EMSs. Part 2 provides additional specifications with regard to the pre-defined communication objects as well as the general communication objects.
Keywordsn/a
DSP817 KiB2014-06-17Login
CiA 454-3 version 2.0.0CANopen application profile for energy management systems – Part 3: PDO communication
DescriptionThis document represents the part 3 of the CANopen application profile for EMSs. Part 3 provides the PDO communication and mapping parameters.
Keywordsn/a
DSP533 KiB2014-06-17Login
CiA 454-4 version 2.0.0CANopen application profile for energy management systems – Part 4: EnergyBus controller (EBC)
DescriptionThis document represents the part 3 of the CANopen application profile for EMSs. Part 3 specifies the application objects provided by the virtual device Energy management system controller (EBC).
Keywordsn/a
DSP176 KiB2014-06-17Login
CiA 454-5 version 2.0.0CANopen application profile for energy management systems – Part 5: Voltage converter
DescriptionThis document represents the part 5 of the CANopen application profile for EMSs. Part 5 provides application objects provided by the AC-DC converter. The AC-DC converter may be implemented to realize a battery charger or a charger station.
Keywordsn/a
DSP859 KiB2014-06-17Login
CiA 454-6 version 2.0.0CANopen application profile for energy management systems – Part 6: Battery pack
DescriptionThis document represents the part 6 of the CANopen application profile for EMSs. Part 6 of the document specifies application objects provided by the battery pack.
Keywordsn/a
DSP518 KiB2014-06-17Login
CiA 454-13 version 1.0.0CANopen application profile for energy management systems – Part 13: - Generator unit
DescriptionThis document represents the part 13 of the CANopen application profile for EMSs. Part 13 of the document specifies generator units such as a diesel engine, photovoltaic generator, winds turbine, etc. Generators shall be divided into two classes: Controllable and stochastic generator.
Keywordsn/a
DSP383 KiB2014-06-17Login
CiA 454-14 version 1.0.0CANopen application profile for energy management systems – Part 14 - Load unit
DescriptionThis document represents the part 14 of the CANopen application profile for EMSs. Part 14 of the document specifies load units such as lighting, electrical motor, radio, refrigerator, washing machine, etc. Loads shall be divided into three classes: controllable loads, influenceable loads and non-controllable loads.
Keywordsn/a
DSP330 KiB2014-06-17Login