“CAN FD light”: A “handler/dog” protocol
The nonprofit CiA (CAN in Automation) association develops a “handler/dog” data link layer based on the CAN FD protocol as specified in ISO 11898-1:2015. The “handler” node implements the CAN FD protocol and sends just 11-bit identifier FD frames. The “dog” nodes transmit data frames in FBFF (FD base frame format) only on request of the “handler” node. This avoids the implementation of high-performance and costly oscillators.
The protocol engine of the “dog” nodes is simplified compared to a CAN FD controller. Error and overload frames are not supported at all. Nevertheless, data fields of up to 64 byte are possible. The bit-rate is not switched and limited to one fixed value, for example 1 Mbit/s.
This commander/heeler approach is suitable for embedded networks in LED devices for passenger cars. Other application examples include door control subsystems and air-conditionings with a lot of sensors.
The CiA Special Interest Group (SIG) is named “CAN FD light”. Fred Rennig from ST Microelectronics chairs the group, which comprises about 20 experts from different companies.
a This is a substitute term for “master/slave”.