CiA® 461 series: CANopen profile for weighing devices

The device profile family for weighing devices specifies the CANopen interface including the PDO mapping and the necessary configuration parameter. Part 1 and part 2 were released CiA-internally as Draft Standard Proposal (DSP) in summer 2015.

Part 1 of this series provides some general definitions including several legal for trade (LFT) modes. It describes also the data encryption and data exchange procedure. Additionally, the sealing and the password changing procedure are described briefly. Of course, this part specifies some common communication parameter of the CANopen interfaces for weighing devices.

Part 2 specifies the CANopen interface for load cells. Load cells are transducers that generate an electrical signal with a magnitude proportional to the measured force. Eight device classes are described. The profile specifies several compensation techniques for gravity, inclination, temperature, and movement acceleration. In case of external compensation, the compensation values are mapped into the four default RPDOs. The two specified default TPDOs provide the load cell weight output value plus weight status and alarm information, respectively the weight status and the process data random number as well as the process data signature. The configuration parameters include the data sample rate and filter settings, for example, for Bessel, Butterworth, or Notch characteristics.

Part 3 of the document deals with the scale devices.

Part 4 is intended for special human machine interfaces and indicator devices related to weighing applications.

Title Details
Status
Size
Published
Action
CiA 461-C1 version 0.0.1CiA profile for weighing devices
Descriptionn/a
Keywordsn/a
WDP474 KiB2019-08-09Login
CiA 461-B1 version 0.0.1CiA profile for weighing devices
Descriptionn/a
Keywordsn/a
WDP3.2 MiB2019-08-09Login
CiA 461-1 version 2.0.1CANopen profile for weighing devices - Part 1: General definitions and PDO specifications
Descriptionn/a
Keywordsn/a
WD0.9 MiB2022-04-12Login
CiA 461-2 version 2.0.1CANopen profile for weighing devices – Part 2: Load cells
Descriptionn/a
Keywordsn/a
WD1.8 MiB2022-04-12Login
CiA 461-3 version 2.0.1CANopen Profile for weighing devices - Part 3: Scales
Descriptionn/a
Keywordsn/a
WD2.6 MiB2022-04-12Login
CiA 461-4 version 2.2.1CANopen profile for weighing devices - Part 4: Human machine interface and indicators
Descriptionn/a
Keywordsn/a
WD739 KiB2022-04-12Login
CiA 461-4 version 2.0.0CANopen profile for weighing devices - Part 4: Human machine interface and indicators
DescriptionThis document specifies the CANopen interface for human machine interface and indicators. This includes process data and configuration parameters as well as PDO communication and mapping parameters.
Keywordsn/a
DSP458 KiB2021-04-19Login
CiA 461-3 Version 2.0.0CANopen profile for weighing devices - Part 3: Scales
DescriptionThis document specifies the CANopen interface for scales. This includes process data and configuration parameters as well as PDO communication and mapping parameters.
Keywordsn/a
DSP1.7 MiB2021-04-19Login
CiA 461-2 version 2.0.0CANopen profile for weighing devices - Part 2: Load cells
DescriptionThis document specifies the CANopen interface for load cells. This includes process data and configuration parameters as well as PDO communication and mapping parameters.
Keywordsn/a
DSP1.0 MiB2021-04-19Login
CiA 461-1 version 2.0.0CANopen profile for weighing devices - Part 1: General definitions and PDOs
DescriptionThis document specifies CANopen interface functionality, general communication parameters and Process Data Objects. It also specifies the lower-layer requirements.
Keywordsn/a
DSP574 KiB2021-04-19Login